PulseVault — Live Wall-Thickness InferenceQueen Bee node · PEXMART Rosslyn · powered by Ipenga Consulting
● MANUAL
ON SPEC
57.3wall mm
+2.0margin mm
0.0overbuild kg
ON SPECWall in the accepted band above ISO minimum — lean and safe.Baseline
Inferred cross-section vs ISO band
eₘᵢₙ — SCRAP line
accepted overbuild ceiling
eₘₐₓ — ISO max
Bore on the red line = wall at minimum (cross it = scrap). Between red & green = the accepted 2–3 mm margin. Past green = flagged overbuild.
Margin over eₘᵢₙ
+2.0 mm
within accepted band
Inferred wall
57.3 mm
ISO band 57.3–63.3 mm
Flagged overbuild — run total
0.0 kg
0.0 kg/hr · 0.0 kg per 12 m length
🐝QUEEN BEE NODE — LIVE INPUTSDIN-rail IoT gateway · streaming to PulseVault
Line speedQUEEN BEE
pulse counter (haul-off)
0.350m/min
Output rateQUEEN BEE
screw RPM / plug-in (R556)
2090kg/hr
Barrel tempQUEEN BEE
Type-K thermocouple #1
198°C
Die tempQUEEN BEE
Type-K thermocouple #2
205°C
Production run — 10 × 12 m lengths (120 m) at real speed
0.0 / 120.0 m produced · run time T+0:00:00 (plant) · 1 length ≈ 34 min at ×1
0good lengths
0scrapped
0scrap kg
0produced kg
Run setup — from ISO 4427 size table (not measured)
Material
Nominal Ø (dₙ)
mm
SDR series
Pressure class
PN16
eₘᵢₙ — SCRAP line
57.3 mm
eₘₐₓ — ISO max
63.3 mm
Accepted overbuild
+ mm
Min mass / 12 m
1182 kg
dₙ and SDR from SANS ISO 4427 / ISO 11922-1. eₘᵢₙ = dₙ/SDR rounded up to 0.1 mm — the scrap line (wall below it loses the pressure class, the 12 m length is scrapped). Everyone accepts ~2–3 mm of wall over eₘᵢₙ; beyond the accepted figure is flagged as overbuild. Die is fixed, so OD/SDR are set, not measured — wall is inferred from the Queen Bee inputs.
The math — live inference from Queen Bee inputs
Min wall (ISO scrap line)eₘᵢₙ = dₙ/SDR ⌈0.1⌉
Min mass/metre(π/4)(dₙ²−ID²)·ρ
Queen Bee mass/metreOutput ÷ (speed×60)
Back-solved boreID = √(dₙ²−(4/π)·A)
Inferred wallWT = (dₙ−ID)/2
Margin over eₘᵢₙ+2.0 mm
Mass conservation: the Queen Bee output (kg/hr) ÷ line speed = the mass in every metre of wall. The inferred wall is the exact inverse of the ISO geometry — no wall sensor needed.
Exception rules — SANS ISO 4427 / ISO 11922-1
State
Rule (inferred wall)
Action
SCRAP
wall < eₘᵢₙ — below ISO minimum, pressure class lost
12 m length scrapped & counted (kg). Line never runs minus on purpose.
SCRAP RISK
eₘᵢₙ ≤ wall < eₘᵢₙ + 0.5 mm — drifting onto the scrap line
Early warning — lift the wall before it scraps.
ON SPEC
eₘᵢₙ + 0.5 mm … eₘᵢₙ + 3.0 mm — the accepted margin
None — running lean and safe.
OVERBUILD
wall > eₘᵢₙ + 3.0 mm, sustained — wasting PE100
Alarm after 60 s → operations. Mass over the accepted band counted (kg).
OVER-TOL
wall > eₘₐₓ — outside ISO dimensional tolerance
Flagged with the overbuild alarm.
The win: because the system warns as the wall drifts toward the scrap line, the operator can hold a tight, safe margin — saving kg on every length without ever scrapping. All alarms are debounced (Queen Bee sample → moving average → persistence → hysteresis); no single noisy reading raises one.
Exception monitoring — debounced alerting engine
Queen Bee sample rate 3 /sec · moving average 1.0 s · averaged margin +2.0 mm
Overbuild: trip > +3.0 mm sustained 60 s, clears when back inside the band
Scrap-risk: within +0.5 mm of eₘᵢₙ sustained 15 s · Scrap: wall < eₘᵢₙ (immediate)
Monitoring — within tolerance
PulseVault alert feed — exceptions pushed to operations